Command Index In Numeric Order
Command Index In Numeric Order With Password Level
For a definition of password levels, refer to “CMD 02: Add Programming Passwords”
CMD | Function | Level |
00 | Print Lists Of Commands | 12345 |
01 | Change System Code | 1 |
02 | Add Programming Passwords | 1 |
03 | Change Selected Keypads | 125 |
05 | Reporting Modes | 125 |
06 | Disable Report Of Grants | 125 |
07 | Change Duress Digit | 1234 |
08 | Change Duress Alarm Mode | 125 |
09 | Generate CODEs With Duress Digits | 1234 |
10 | Add Access User (Keypad Only – IDF 1) | 123 |
11 | Redefine Access User | 123 |
12 | Change Any User Access or Control Zone | 123 |
13 | Change Any User CODE | 123 |
14 | Add or Change Duress Digit for User or Range of Users | 123 |
15 | Add Unlock/Relock User | 123 |
16 | Delete Any User | 1234 |
17 | Define Standard Access Zone – 1 Time Zone All Doors | 12345 |
18 | Change CODE Length For Auto-Generation | 1234 |
19 | Auto Add Access User (Auto-Gen Code) | 123 |
20 | Auto Add Access User (Auto-Select User Number) | 123 |
21 | Auto Add Multiple Access Users (Auto-Gen Code & User Number) | 123 |
22 | Auto Add Multiple Access Users (Auto-Gen From Specified User Number) | 123 |
23 | Delete Range Of Users | 1234 |
24 | Define Standard Access Zone – 1 Time Zone Per Door | 12345 |
30 | Print User Without CODE | 1234 |
31 | Print Users Without CODE | 1234 |
32 | Print First Available User Number | 1234 |
33 | Print Users Given Access or Control Zone | 1234 |
34 | Print Families Of Users Without CODE | 1234 |
35 | Print User With CODE | 123 |
36 | Print Users With CODE | 123 |
37 | Print User Given CODE | 123 |
38 | Print Families Of Users With CODE | 123 |
40 | Add Relay Control User | 123 |
41 | Add Top-Priority Relay Control User | 123 |
42 | Add Alarm Control User | 123 |
43 | Add Keypad Index Control User (IDF 1) | 123 |
44 | Add Special Control User | 123 |
45 | Define Standard Control Zone | 12345 |
46 | Change Passback Mode | 125 |
47 | Forgive Passback For User | 1234 |
48 | Forgive Passback/Occupancy Count For All Users | 1234 |
49 | Tag Any User | 1234 |
50 | Set Date & Day Of The Week | 12345 |
51 | Set Time | 12345 |
52 | Define Standard Time Zone | 12345 |
54 | Define Master Time Zone | 12345 |
56 | Clear Time Zone | 12345 |
57 | Define Holiday | 12345 |
58 | Clear Holiday | 12345 |
59 | Clear All Holidays | 12345 |
70 | Enable Selected Line Module Inputs | 125 |
71 | Disable Selected Line Module Inputs | 125 |
72 | Change Selected Line Module Inputs | 125 |
73 | Change Selected RQEs | 125 |
74 | Change Door Open-Too-Long Interval | 125 |
75 | Door Open-Too-Long Active While Unlocked | 125 |
76 | Mask Line Module Input During Time Zone | 125 |
77 | Change CODE Tamper | 125 |
78 | Change Alarm Relay Mapping | 125 |
79 | Change Time For Alarm Relay | 125 |
80 | Change Door Time for Relay | 125 |
81 | Change Control Time Of Relay | 125 |
82 | Time Zone Control Of Relay | 125 |
83 | Clear Time Zone Control Of Relay | 125 |
84 | Line Module Input Triggers Control Zone | 125 |
85 | Change Line Module Input/Relay Contacts for Selected Relays | 125 |
86 | Change Relay & Line Module Input Operating & Reporting Mode | 125 |
87 | Relay Triggers Control Zone | 125 |
88 | Print System Setups and Status | 12345 |
90 | Maintenance | 12345 |
96 | Terminate Command In Progress | 12345 |
98 | Upload/Download Setup Commands | 12345 |
99 | Quit Programming | 12345 |
103 | Change Selected MATCH Functions | 125 |
104 | Enable CARD-Only At Dual Technology Reader During Time Zone | 125 |
105 | Disable Device During Time Zone | 125 |
106 | Disable Reporting During Time Zone | 125 |
107 | Daily Report Mode | 125 |
108 | Time Zone Control Of Modem | 125 |
109 | Invalid Code Reporting Mode | 125 |
110 | Change Entry/Exit Delay For Line Module Input | 125 |
111 | Change Entry/Exit Delay Time For Expansion Line Module Input | 125 |
112 | Disable Entry Delay For Line Module Input During Time Zone | 125 |
113 | Disable Entry/Exit Delay Time For Expansion Line Module Input During Time Zone | 125 |
117 | Define Standard Access Zone – 1 Time Zone Specified Doors Only | 1235 |
124 | Define Standard Access Zone – 1 Time Zone Per Reader | 1235 |
140 | Set Report Buffer Alarm Threshold | 12 |
146 | Disable Passback/Occupancy Count During Time Zone | 125 |
149 | Alert Users | 1234 |
154 | Define Grand Master Time Zone | 12345 |
170 | Enable Expansion Line Module Input | 125 |
171 | Disable Expansion Line Module Input | 125 |
172 | Change Expansion Line Module Input | 125 |
173 | Change Expansion RQE | 125 |
174 | Change DOTL Timer Of Expansion Line Module Input | 125 |
175 | Expansion DOTL Always Active | 125 |
176 | Mask Expansion Line Module Input During Time Zone | 125 |