Identiv EG-2 Release Notes 1.1
IDENTIV EG-2 (Model 50-40-SB) Certified Version 1.1 Release Notes
Version 1.1 – Certified Release Thursday, August 24, 2023
IDENTIV EG-2 (Model 50-40-SB) is compatible with Primis and Primis Cloud Version 11.4 Only (Not supported on Freedom or Freedom Cloud)
IDENTIV EG-2 (Model 50-40-SB) Overview
The new IDENTIV EG-2 (Model 50-40-SB) is an IT-based door controller designed to manage all local access control seamlessly while integrating with any existing IT network infrastructure. Powered by 24 VDC or PoE+, the IDENTIV EG-2 (Model 50-40-SB) can connect with any Primis Cloud or Primis on-premise cube, regardless of its location, offering a wide variety of distributed topologies to suit any requirements. While connected to a Primis instance, the IDENTIV EG-2 (Model 50-40-SB) stores all the information required to provide access to its managed doors. In the event of a loss of connection to Primis, the IDENTIV EG-2 (Model 50-40-SB) retains its information, ensuring no downtime in operations or access for cardholders.
Specifications
Parameter | Details |
Dimensions | 205 x 115 x 45 mm (8 x 4.5 x 1.75 in) |
Power Requirements | 24VDC (120W supply) or PoE+ |
Power for Attached Devices | Up to 25.5W total |
Credential Capacity | 500,000 |
Log Capacity (Offline Mode) | 100,000 |
Operating Temperature | 0° to 49° C (32° to 120° F) 93% relative humidity |
Weight | 1.1 LBS |
Lock Power Available | 12/24 VDC - 12W (1A @ 12V, 0.5A @ 24V) |
Communication | Ethernet (10/100/1000) 1GbE |
Network Protocols Supported | IPv4, DHCP, DNS, NTP |
Network Encryption | TLS 1.2 |
Number of Readers Supported | 2 |
Reader Type | Wiegand or OSDP v2.1.5 or later |
Reader Power Available | Up to 500mA per reader |
Inputs | Up to 9 (configurable via line module) |
Relay Outputs | 3 |
Relay Switch Capacity | 2A @ 30VDC |
Compliances | PENDING: UL294, UL2043, FCC Part 15 Class B, ICES-003, KS C 9832, EN 55032, TAA |
Part Number | FR-50-40-SB |
New Features
KEY FEATURES IN THIS RELEASE
Support for up to 2 readers (2 OSDP or 2 Wiegand).
Support for up to two doors with entry readers only or one door with entry/exit readers.
Support for 3 relays, two doors relays, and one auxiliary relay.
Support for up to 9 supervised inputs (Three per door and Three auxiliary) using IDENTIV DTLM3 and/or MELM3 modules.
Support for Identiv DTLM1, DTLM2, DTLM3, MELM1, MELM2 and MELM3 line modules.
Support for up to 500,000 credentials.
Support for log capacity of 100,000 transactions when offline from Primis.
Support for Enclosure tamper detection.
Support for Reader tamper detection.
Support for 24VDC or PoE+ input.
Support for 24VDC and 12VDC outputs for Lock Power.
Support for LED status indicators for Readers, Inputs, Outputs, EG-2 state, Network, Power, and OSDP RS485 status.
Support for software and firmware updates from Primis.
Support for Global Input/Output linking - peer to peer communications among IDENTIV EG-2 (Model 50-40-SB).
Support for secured TLS/MQTT network communications.
Support for TLS Certificate management.
Support for continued local operations while offline from Primis.
Support for OSDP V2.1.5 or later Secure Channel.
Support for the IDENTIV Bridge Utility configuration tool.
Support for direct NTP server configuration.
Support for Primary and Secondary Server configuration.
Support for Name Server configuration and resolution.
Support for Principal and Replica IDENTIV EG-2 (Model 50-40-SB) configuration.
Support for onboard logging.
Support for PoE voltage, input voltage, door current, clock battery, and IDENTIV EG-2 (Model 50-40-SB) temperature monitoring in Primis.
Support for locating ping.
Support for IDENTIV EG-2 (Model 50-40-SB) remote reboot.
Support for IDENTIV EG-2 (Model 50-40-SB) remote software and firmware upgrade.
Support for configurable IDENTIV EG-2 (Model 50-40-SB) sync schedules.
Support for RS485 OSDP address conflicts displayed in Primis.
Compliant with (pending) UL294, UL2043, FCC Part 15 Class B, ICES-003, KS C 9832, EN 55032, TAA.
IDENTIV EG-2 (Model 50-40-SB) online status is now CYAN instead of VIOLET.
Known Issues
The reader buzzer managed by the IDENTIV EG-2 (Model 50-40-SB) is not supported in this release.
Exit reader multi-factor is not supported in this release.
Not all database records are synchronized in real-time, they are scheduled.
OSDP readers do not function when IDENTIV EG-2 (Model 50-40-SB) does not have a database downloaded.
IDENTIV EG-2 (Model 50-40-SB) displays erroneous “Up Time” during boot-up and when the MQTT connection is not ready.
Special day schedules are not supported in this release.
The silkscreen on the top case will differ from that shipped in the Release Item.
Anti Passback is not available.
Alert level handling is not available.