80X0 uTrust Touch Secure Mullion Reader

Search

 

Introduction


This document details the Physical Access Control Reader TouchSecure® and its basic operational and installation procedures. It covers the details of the Mullion form-factor reader.
Model: Connectivity/Standard MUL.

  • The reader comes in two variants for interfacing with the control panel:

    • Pigtail - 8000ABP, 8010ABP

    • Phoenix connectors - 8000ABT, 8010ABT, 8030ABC

    • P - refers to Pigtail, T - refers to Terminal (Phoenix header)

  • The reader comes in three variants in functionality

    • Standard HF Only - 8000ABP, 8000ABT

    • Standard HF LF - 8010ABP, 8010ABT

    • Connectivity HF LF - 8030ABC

    • P - refers to Pigtail, T - refers to Terminal (Phoenix header), C - refers to connectivity

    • In connectivity, Only Terminal version is available

Reader

Functionality


TouchSecure reader is a physical access control smart card reader that can read HF and LF contactless credentials, conforming to the following standards: ISO 14443 A & B, ISO15693. The reader can interface with an access control system equipped with a Wiegand or RS-485 serial interface.

Reader parts


The reader consists of the following main parts:

a. Top Casing

 

b. Touch Screen Reader with Bottom Casing

Reader variants


Product Details


Model Name

Connectivity/Standard MULLION.

Device Type

RFID reader, 13.56MHz (HF) / 125 KHz (LF).
Physical Access control Reader (accessory equipment).

Type of equipment

Potted reader.
Suitable for Indoor use - 8030ABC and
Outdoor use - 8000ABP, 8000ABT, 8010ABP, 8010ABT.

Interface Type

Pigtail Cable (11 Core + Drain) or Phoenix connectors and RJ45.

Voltage Rating (8030ABC)

6-16VDC or 48VDC on RJ45 Connector.

Voltage Rating (All other models)

5-16VDC.

Communication protocol

Wiegand, RS-485 (2wire - Half Duplex), 10BaseT ETH.

* Communication via Wiegand and OSDP was evaluated by UL and serves as the interface between the reader and panel, Communication via Ethernet was not evaluated by UL.

Reader Specifications


Model

Operating Voltage

Current rating

Operating temp

Model

Operating Voltage

Current rating

Operating temp

8000ABP
8000ABT
STANDARD HF ONLY

5 - 16VDC

Refer graph in section

 

 

 

-35 to +65 Deg C

8010ABP
8010ABT
HF LF

5 - 16VDC

8030ABC
HF LF
CONNECTIVITY

6 - 16VDC

 

 

0 to +49 Deg C

PoE @ 48VDC

*PoE sourcing equipment shall be UL 294 or UL 294B Listed with Class 2 output.

  • When the readers use PoE as a power source, the power input wiring from the control unit (i.e. Red and Black for 8030) shall be disconnected.

  • The maximum length of the Ethernet cable when using PoE as the power source in UL installations is limited to 30 meters (98.5 feet).

Standby Power is not provided by the Card Readers. The Standby Power Level is dependent on the external power source connected to the Card Reader.

  • All wiring or cables to the Card Readers shall be the shielded type.

  • Only UL Listed PoE sourcing equipment, or UL Listed power-limited power supply, or power-limited output from UL Listed control panel shall be used for the Power Over Ethernet feature. Cat 5e cabling is the minimum performance category recommended. These Card Readers when using PoE feature are not intended for outside wiring as covered by Article 800 of the US National Electrical Code, NFPA 70.

Rated current at different operating voltages

Rated current for Model 8000


Voltage (V)

Average Current (mA)

Peak Current (mA)

Voltage (V)

Average Current (mA)

Peak Current (mA)

5V

150 mA

187 mA

8V

159 mA

208 mA

10V

122 mA

164 mA

12V

100 mA

133 mA

14V

87 mA

118 mA

16V

77 mA

103 mA

Rated current for Model 8010


Voltage (V)

Average Current (mA)

Peak Current (mA)

Voltage (V)

Average Current (mA)

Peak Current (mA)

5V

150 mA

187 mA

8V

159 mA

208 mA

10V

122 mA

164 mA

12V

100 mA

133 mA

14V

87 mA

118 mA

16V

77 mA

103 mA

Rated current for Model 8030

Rated current for 6-16v Input

Voltage (V)

Average Current (mA)

Peak Current (mA)

Voltage (V)

Average Current (mA)

Peak Current (mA)

6V

273 mA

308 mA

8V

251 mA

292 mA

10V

219 mA

273 mA

12V

167 mA

211 mA

14V

144 mA

178 mA

16V

128 mA

158 mA

Rated current for POE

Voltage (V)

Average Current (mA)

Peak Current (mA)

Voltage (V)

Average Current (mA)

Peak Current (mA)

37V

65 mA

70 mA

48V

50 mA

55 mA

57V

45 mA

50 mA

Installation Details


Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.

Parts List


  • TouchSecure®reader - 1.

  • Screws (A #6-18X1.5" SS ) - 2Nos - Mounting screws for Wall.

  • Snake Eye Screw (SMF #6-32X5/16" SS) - Top casing mounting security screw.

  • Screws (SMF #6-32x3/8" SS) - 3 No’s - 1 Top casing mounting screw and 2 Junction Box mounting screws.

  • Nylon anchor plug - 2 Nos.

  • 6 pin phoenix plug (Phoenix connector version only) - 2 Nos.

Recommended Infrastructure


All cabling and wiring shall be UL Listed and/or UL Recognized

  • All readers shall be powered by UL listed PoE sourcing equipment, UL listed power-limited power supply, or power-limited output from UL listed control panel

Cable Wiegand

22AWG Shielded cable. ( Cable P No : ALPHA WIRE, P/N 1299/10C)

Cable RS-485

RS-485 for 1000m** (4000ft) 24AWG STP

Cable RJ45

Cat5e / Cat6

Linear DC PS

5 - 16V, 1A min.

** Tested in lab conditions up to 115Kbaud

Wiring Information

Cable Color codes for Pig Tail Reader


Table 1

& Do not connect when reader is powered by Power over Ethernet.

Pin out for Phoenix Connector Reader


Table 2

Pin

Cable color

Description

Comment

Pin

Cable color

Description

Comment

P1.1

Orange

LED Green

 

P1.2

White

Data 1

 

P1.3

Green

Data 0

 

P1.4

Black

Drain

Drain to be connected to cable shield

P1.5

Black + White

Gnd

 

P1.6

Red

Power

Do not connect when reader is powered by PoE

P2.1

Blue

Hold

 

P2.2

Violet

Tamper

 

P2.3

Gray

RS485-

 

P2.4

Pink

RS485+

 

P2.5

Yellow

Buzzer

 

P2.6

Brown

LED Red

 

During Wiring make sure that the +VDC lines does not make contact with any other cables, as it might affect reader functionality/ cause damage to the reader.

Mounting the Reader

Location of mounting holes on wall


Reader Installation Steps


Make two holes on the wall as per the image above corresponding to the type of reader.
b. Insert the nylon screw plugs into the wall.
c. Connect the wires as per the Table 1 or Table 2.
d. TouchSecure® reader with Bottom Casing is to be now secured onto the wall using the Screws (A #6-18X1.5" SS ).
e. The top casing can be inserted onto the bottom casing.
f. Secure the Top and bottom casing by the Snake Eye Screw (SMF #6-32X5/16" SS).

Power up and Testing


  1. Turn power on
    The LED blinks 3 times green with a long beep, then turns red

  2. Present a card
    The LED blinks green, and a short beep is emitted

This is the default reader behavior.

 

Certifications

FCC


This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Re-orient or relocate the receiving antenna.

  • Increase the separation between the equipment and receiver.

  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

  • Consult the dealer or an experienced radio/TV technician for help.

Information to user
Changes or modifications not expressly approved by Identiv could void the user's authority to operate the equipment.

IC


This Class B digital apparatus complies with Canadian ICES-003.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.

CE


Identiv hereby declares that the TouchSecure® Model: Connectivity MUL device mentioned herein is in compliance with the essential requirements and other relevant portions of the Directive R&TTE 1999/5/EC.

UL 294


Communication via Wiegand and OSDP was evaluated by UL and serves as the interface between the reader and panel

  • Communication via Ethernet was not evaluated by UL.

  • The maximum length of the Ethernet cable when using PoE as the power source in UL installations is limited to 30 meters (98.5 feet).

UL 294 Access Control Performance Levels

Destructive attack

Level IV

Line Security

Level I

Endurance

Level I

Standby Power

Level I



Related pages