Functionality


TS KEYPAD reader is a physical access control smart card reader that can read HF and LF contactless credentials, conforming to the following standards: ISO 14443 A & B, ISO15693 with a keypad PIN entry for additional security. The reader can interface with an access control system equipped with a Wiegand or RS-485 serial interface. It can also be interfaced with a Host Sever / Control Panel that supports Ethernet interface. User interfaces include RGB LED’s and Buzzer.

Reader Parts

a. Front/Top Casing and Back View

b. Back plate


Product details


Model Name

uTrust TS Keypad

Device Type

RFID reader, 13.56 MHz (HF) / 125 KHz (LF), keypad
Physical Access control Reader (accessory equipment)

Type of Equipment

Potted Reader, Suitable for Indoor use

Interface Type

Phoenix connectors and RJ45

Voltage Rating

6 - 16VDC (or) 48VDC on RJ45 Connector

Current Rating @ 12V

Peak Current - 255 mA

Average Current - 180 mA

Communication Protocol

Wiegand, RS-485 (2wire - Half Duplex), 10BaseT ETH

Specifications


Model

Operating Voltage

Current @ 12V

Operating Temp

Operating Humidity

Model

Operating Voltage

Current @ 12V

Operating Temp

Operating Humidity

 

8230
uTrust TS
KEYPAD

6 - 16VDC

Av - 180 mA @ 12V
Pk - 255 mA @ 12V
Refer Section “Rated current at different operating voltages” for detailed ratings at various voltages

 

 

0 to +49C

 

 

85 +/-5 % RH

PoE @ 48VDC*

80 mA Max.

*PoE sourcing equipment shall be UL 294 or UL 294B Listed with Class 2 output

  • When the readers use PoE as a power source, the power input wiring from the control unit (i.e. Red and Black for 8230) shall be disconnected

  • The maximum length of the Ethernet cable when using PoE as the power source in UL installations is limited to 30 meters (98.5 feet)

Rated current at different operating voltages


Voltage (V)

Average Current (mA)

Peak Current (mA)

Voltage (V)

Average Current (mA)

Peak Current (mA)

6V

300 mA

360 mA

8V

283 mA

348 mA

10V

241 mA

300 mA

12V

180 mA

255 mA

14V

162 mA

220 mA

16V

142 mA

195 mA

Label


During Wiring make sure that the +VDC lines does not make contact with any other cables, as it might affect reader functionality/cause damage to the reader.

Installation details


Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.

Parts List


  • TS Keypad reader - 1

  • Screws (A #6-18X1.5" SS ) - 4 No's - Back Plate mounting screws for Wall

  • Snake Eye Screw (SMF #6-32X5/16" SS) - 1 No- Top casing mounting security screw

  • Screws (SMF #6-32x3/8" SS) - 3 No’s - 1 casing to back plate mounting screw and 2 junction box mounting screws

  • Nylon anchor plug - 4 No's

  • 6 pin phoenix plug (Phoenix connector version only) - 2 No's

  • Back Plate

Recommended Infrastructure


  • All cabling and wiring shall be UL Listed and/or UL Recognized

Cable Wiegand

22 AWG Shielded cable. (Cable P No : ALPHA WIRE, P/N 1299/10C)

Cable RS-485

R485 for 1000m** (4000ft) 24 AWG STP

Cable RJ45

Cat5e / Cat6

Class 2 Linear DC PS

6 - 16V, 1A min.

** Tested in lab conditions up to 115K baud

Connector Information

Pinout diagram


Table 1

-Shield Ground/Drain - Black color should be connected to the cable shield.

During Wiring make sure that the +VDC lines does not make contact with any other cables, as it might affect reader functionality/cause damage to the reader.

Mounting the Reader

Location of Mounting Holes on Wall


Reader Installation Steps


a. Make holes on the wall as per the image above
b. Insert the nylon screw plugs into the wall
c. Connect the wires as per the Table 1
d. TouchSecure® reader with bottom casing is to be now secured onto the wall using the Screws (A #6-18X1.5" SS)
e. The top casing can be inserted onto the bottom casing
f. Secure the Top and bottom casing by the Snake Eye Screw (SMF #6-32X5/16" SS)

Power Up and Testing


1 Turn power on
The LED blinks 3 times green with a long beep, then turns red.
2 Present a card
The LED blinks green, and a short beep is emitted.
3 Press Key
Buzzer tone & backlight LED blinks.
This is the default reader behavior.

Certifications

FCC


This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna

  • Increase the separation between the equipment and receiver

  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected

  • Consult the dealer or an experienced radio/TV technician for help


Information to user
Changes or modifications not expressly approved by Identiv could void the user's authority to operate the equipment.

IC


This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference
(2) This device must accept any interference, including interference that may cause undesired operation of the device

UL 294 and UL 1076


  • Communication via Wiegand and OSDP was evaluated by UL and serves as the interface between the reader and panel

  • Communication via Ethernet was not evaluated by UL

  • The maximum length of the Ethernet cable when using PoE as the power source in UL installations is limited to 30 meters (98.5 feet)

  • When the reader is powered by a supply other than Identiv Mx series controller, the power supply should be a UL 294 and 1076 listed , class 2 supply.

  • For UL 1076, the reader was assessed for the acknowledgment signal annunciation while interfacing to the Listed Identiv Mx series control unit via Wiegand and OSDP

UL 294 Access Control Performance Levels


Destructive Attack

Level IV

Line Security

Level I

Endurance

Level I

Standby Power

Level I

 