When an operator first launches to Velocity, the first task is to make connection to the Velocity database in SQL Server.

image-20240718-211200.png

Velocity reads the value called SQL Server at the follow Windows Registry location and tried to make a connection to the SQL instance.

Computer\HKEY_LOCAL_MACHINE\SOFTWARE\WOW6432Node\Hirsch Electronics\Velocity\Client
image-20240718-211436.png

Troubleshooting

  • Check to see if the the SQL Server service is running. If it is not running, start the service.

image-20240718-205723.png
  • Using Microsoft’s TCPView from the Sysinternals suite. Can help trouble shoot potential issues with network connection. In the below example, we can see Velocity performed a Sys Sent, but did not receive a message back from the SQL Server.

image-20240718-212048.png
  • Launching SQL Server Management Studio and trying to connect to the SQL Instance can also provide useful information regarding reasons you are unable to connect to the SQL Instance.

image-20240718-212619.pngimage-20240718-212953.png