PRIMIS EG-2 Release – Version Beta 1.2 RELEASE NOTES
June 2023 |
PRIMIS EG-2 Release Notes – June 2023
o PRIMIS server will now support Timezone for the US (Hawaii, Alaska, Pacific, Mountain, Central, and Eastern), Australia (Western, Central Western, Central, and Eastern), and India.
o Card read performance improved. Bridge mode takes 240 msec while controller mode takes just 220 msec.
o Reset switch action: 2 seconds - STM reset, 5 seconds – EG-2 Reboot, and 20+ seconds - Factory reset. Tolerance of 7 seconds for EG-2 reboot.
o Fixed PTA not triggering relay action when it is not in principal/replica configuration.
o EG-2 will now send events for door module and reader module reboot, device module reboot, user STM reset, and tamper secure events.
o 32-bit IR clicker card format support added.
o Port lookup issue during enclosure tamper event.
o Fixed database sync crash issue when exporting badge templates to EG-2.
o API “DeviceModuleGetSpiData” will now return 0 when there is no data to fetch.
Feature List
PRIMIS server Lite BETA
o Use mDNS to help with device discovery over UDP.
o Suspend port triggering on SB when in controller mode.
o FMI (first-main-in) requires the User Access Group to proceed.
o Network speed LED.
o Offload SerialIO direction bit control to OS.
o FB3 support.
o Read the DHCP address after the LAN cable is plugged in.
o Delete freedom.db and gz files during factory reset.
o Sync controlled area status with PRIMIS server after re-connection.
o Tamper detection.
o In controller mode, send/backlog tamper, linerror, and inputevent messages to PRIMIS server after re-connection.
o Input Sensor LED.
o Live DB Update on Special Days (Holidays).
o Live DB update on Devices table.
o Live DB update on Controlled Areas.
o Live DB update on Schedules and Zone(controlled area) Schedules.
o Factory Reset of SB sets the HOSTNAME field in network.conf to a unique convention.
o Global IO Implementation.
o OSDP in Bridge Mode - card swipe events are forwarded to PRIMIS server for access processing.
o Speed up OSDP poll interval.
o STM reset via reset button.
o Fix OSDP Reader set left justification Wiegand issue.
o Analog values (e.g. voltage, temperature) are reported to PRIMIS server.
o Use OSDP built-in LED blink feature to handle multi-factor prompts.
o Increase event backlog size to 100K.
o Current Live DB update will be pushed to SB when SB re-connects to PRIMIS server.
o Missing interrupt problem was resolved.
o Buffer overflow issue was resolved.
o EnforceExitAccessRight is being transferred to SB properly.
o Fix issue with PTA is not able to cross activate relay over the Global IO network.
o Fix PTA schedule handling in controller mode.
o Capture and report STM communication error statistics (e.g. CRC, Timeout) to PRIMIS server every 24 hours.
Freedom Core
o SB is able to report Controlled Area status back to PRIMIS server after re-connection.
o EXIT reader port usage cache is updated immediately after configuration.
o CSV reports for Wifi Controlled Areas.
o Ensure proper chronological order in logs.
o Live DB update on controlled area schedules.
o Live DB update on schedules.
o Live DB update on controlled areas.
o Live DB update on user access groups.
o Live DB update on special days.
o Live DB update on devices.
o Live DB updates for Card and PIN.
o Use mDNS protocol to discover device names and IPs, then use direct UDP/IP to connect to SB's.
o "Sanitize" download file names by replacing special characters to "_"
o Implement two additional reader-tampered input ports.
o Report RS485 Address Conflicts in PRIMIS server GUI.
o In controller mode, send/backlog tamper, linerror, and inputevent messages to PRIMIS server after re-connection.
o Fix "Bridge OffLine" error icon when OSDP readers are offline.
o Optimize the database export on a larger number of users.
o OSDP bridge mode card tag implementation.
o OSDP bridge mode keypad entry implementation.
o Auto DB update when the device is replaced.
o Report Unlock schedule events as door/schedule events.
o Add "Device Offline" to ActivityEvent message field when the bridge device is not connected.
o Report battery status (voltage, charging, etc) available to the PRIMIS Server.
o When executing the bridge mode Multi-factor prompt, let SB handles it using the on/off timered LED command.
o Update the database schema to accommodate hashed card data and PIN data.
o Disallow EXIT when Zone is in LOCKDOWN.
o Synchronize Unlock schedules and controlled area status when SB re-connects to PRIMIS server.
o PRIMIS server GUI - Controlled Area should be flagged (e.g. alert icons) when devices involved are off-line.
o Purge old DB backup files.
o Access request performance optimization.
Limitations and Known Issues
o OSDP readers do not work when EG-2 has no DB downloaded.
o EG-2 shows huge “Up Time” during boot up and when the MQTT connection is not ready.