Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Table of Contents
maxLevel2

...

CMD 05: REPORTING MODES

Syntax:

START 05 * NN # (v7)
START 05 * NN [* 1/0] # (v6.6)

Variables:

NN

1      Disable Relay State Changes

...

11    VELOCITY SCRAMBLE*NET Protocol

1/0 (v6.6 only)
1      Enable mode listed above    (05*8*0# now disables all)
0      Disable mode listed above   (05*8*1# now enables all)

...

Syntax:

START 06 * N * DOORS # (v6.6 and earlier)

START 06 * 1 * DOORS(Access) * DOORS(RQE) # (v7)

Variables:

N
1 Access
2 RQE

Description:

...

Syntax:

START 18 * Length # (Version 6.6 and earlier)

START 18 * Length * [Card Length] # (Version 7)

Variables:

Length

Allowed length for the auto-generation of keypad (PIN) codes.

...

CMD 59: CLEAR ALL HOLIDAYS

Syntax:

START 59 #  (Version 6.6 or earlier)

START 59 * YYYY#  (Version 7)

Variables:

YYYY

Year you want cleared including all four possible holidays.

...

This command is active in V6.6 or later.

Example:

START 78 * 1 #

...

The Control Timer can be momentary with an adjustable time of 1-8100 seconds. It can also toggle a relay ON and OFF on consecutive Control Trigger Code entries if its time is set to 0 (zero) seconds. A Relay's Control Time is used by Control Trigger Codes as well as by a line module input or relay to trigger a Control Zone.

In Version 6.6 and later, you can specify up to 8 relays with the same command, where each relay is separated by asterisks. The second through eighth relay arguments are optional.

...

CMD 88: PRINT SYSTEM SETUPS AND STATUS

Syntax:

START 88 * NN # (Version 6.6 or earlier)

START 88 * NN [* First * Last] # (Version 7)

Variables:

NN
0 Complete System Setups and Status
1 Date, Time, Version Number
2 System Information
3 Standard Time Zones
4 Master Time Zones
5 Standard Access Zones
6 Standard Control Zones
7 Relays
8 Alarm / RQE Inputs
9 Alarm Special Setups and Status
10 Doors
11 Keypads / MATCH
12 MATCH
13 Holidays
14 Grand Master Time Zones
15 Master Access Zones
16 Master Control Zones
17 Detailed Relay Status Only
18 Expansion Relays
19 Detailed Expansion Relay Status Only
20 Expansion Alarm / RQE Inputs
21 Expansion Alarm Special Setups and Status
22 Expansion Line Module Input Door Setups
23 Reporting Setups
24 Remote Site Management Setups
25 System Power Status (of AC power, standby battery, and memory battery)
26 Transactions Since Midnight
27 Occupancy, Passback, Two-Person Rule Controls
28 Virtual Relays
29 Detailed Virtual Relay Status
30 HEC Factory Diagnostics
31 Special Needs Unlock Extension Times
32 Special Keypad / MATCH Setups
33 Special MATCH card mapping

First / Last

All NN subcommands that support this option are marked in italics above.

Description:

Printing a full or partial system status report lists setups, internal status, and event summaries. This report is auto-generated on every Sunday at midnight. An abbreviated version is automatically printed each day at midnight unless disabled by command.

...

NN
1 - Set Up Serial Printer
2 - Set Default Encryption Key
4 - Set Host Password
5 - Change Buffer Control
6 - Enable/Disable System Code Reset
7 - Enable/Disable Command Echo
8 - Set Host Timeout
9 - Set No Midnight Report
10 - Set SCIB extension options (Version 6.6 and later)

Description:

This command provides a way to change several important controller features. Each of these variables requires a slightly different syntax and is explained in more detail on the following pages.

...

Disables midnight report generation.

Default:

In V6.6, all midnight reports are disabled by default. In V6.6 and later, enabled is the default.

...