This document is an installation and operational reference guide for Enterphone 19, Enterphone 21, and EnterphoneiQ panels, and Enterphone Kiosks.

...

Enterphone iQ

Enterphone 19

Image RemovedImage Added

Choosing an appropriate install location

...

Secure the unit to the wall using the supplied screws. If some screws are using wall anchors, secure the screws to the wall studs first.

Ground Connection

All Enterphone models have an earth-ground connection which must be permanently connected to building earth by a skilled person. Refer to “E. Protective Earth” in Fig 1 and Fig 2 to make the connections.

Section 4: Powering Up Your Panel and Kiosk

...

Table 1: Technical Specifications

 

Screen Size

(inches)

Overall Dimensions (inches)

Weight

Operating Temperature

Power Requirements

Touch Function

Capabilities

EnterphoneTM

Kiosk

19 in

50.0 x 18.0 x 12.0

96 lbs

0o – 49o C

24v AC, 40 VA min

YES

EnterphoneTM

19

19 in

20.87 x 16.47 x 4.0

21 lbs

0o – 49o C

24v AC, 40 VA min

YES

EnterphoneTM

IQ

10 in

16.5 x 12.5 x 3.4

16 lbs

0o – 49o C

24v AC, 40 VA min

NO

Figure 3: DIP Switches, Voltage Output Selection

...


OUTPUT

VOLTAGE

SWITCH POSITION

TRANSFORMER REQUIREMENTS

SW 1

SW 2

6 VDC

ON

OFF

16VAC / 40VA (TP1640)

12 VDC

OFF

OFF

24VAC or 28VAC / 100VA (T2428100), or 16VAC / 100 VA (T16100) IDENTIV FACTORY DEFALUT DEFAULT SETTING – DO NOT ALTER

24 VDC

OFF

ON

28VAC / 175VA (T2428175)

Figure 4: Connector E

...

 

CONNECTOR

INPUT / OUTPUT / DESTINATION

DT 1

Door Trip 1

DT 2

Door Trip 2

GND

Door Trip 1 Ground

EB 1

Exit Button 1

EB 2

Exit Button 2

GND

Door Trip 2 Ground

GPO 1

General Purpose Output 1 – IDENTIV INTERNAL USE ONLY

GPO 2

General Purpose Output 2 – IDENTIV INTERNAL USE ONLY

LOCK

Postal Lock

GND

Postal Lock Ground

Figure 5: Door Strike Relay Connector (Connector F)

...

 

CONNECTOR

INPUT / OUTPUT / DESTINATION

+12 V

12 V DC From Power Supply

GND

Ground Input from Power Supply

NC 1

Relay 1 – Normally Closed

COM

Common

NO 1

Relay 1 Normally Open

NC 2

Relay 2 Normally Closed

COM

Common

NO 2

Relay 2 Normally Open

Figure 6: Connector G

...

CONNECTOR

INPUT / OUTPUT / DESTINATION

SPK +

Positive output to speaker

SPK -

Negative output to speaker

AIN 2

Audio input from Processor

GND

Ground input from Processor

MIC

Positive input from microphone

GND

Negative input from microphone

Figure 7: Connector L – Keypad Connection - 19, iQ only

...

 

CONNECTOR

INPUT / OUTPUT / DESTINATION

GND

BLUE WIRE TO PIN 1 – Right to Left on KEYPAD, Right to Left on DIALER BOARD.

COL 2

Number Inputs Column 2

ROW 1

Number Inputs Row 1

COL 1

Number Inputs Column 1

ROW 4

Number Inputs Row 4

COL 3

Number Inputs Column 3

ROW 3

Number Inputs Row 3

ROW 2

Number Inputs Row 2

...