OUTPUT

VOLTAGE

SWITCH POSITION

TRANSFORMER REQUIREMENTS

SW 1

SW 2

6 VDC

ON

OFF

16VAC / 40VA (TP1640)

12 VDC

OFF

OFF

24VAC or 28VAC / 100VA (T2428100), or 16VAC / 100 VA (T16100) IDENTIV FACTORY DEFAULT SETTING – DO NOT ALTER

24 VDC

OFF

ON

28VAC / 175VA (T2428175)

Scroll pagebreak

Figure 4: Connector E

...

 

CONNECTOR

INPUT / OUTPUT / DESTINATION

DT 1

Door Trip 1

DT 2

Door Trip 2

GND

Door Trip 1 Ground

EB 1

Exit Button 1

EB 2

Exit Button 2

GND

Door Trip 2 Ground

GPO 1

General Purpose Output 1 – IDENTIV INTERNAL USE ONLY

GPO 2

General Purpose Output 2 – IDENTIV INTERNAL USE ONLY

LOCK

Postal Lock

GND

Postal Lock Ground

Scroll pagebreak

Figure 5: Door Strike Relay Connector (Connector F)

...

CONNECTOR

INPUT / OUTPUT / DESTINATION

+12 V

12 V DC From Power Supply

GND

Ground Input from Power Supply

NC 1

Relay 1 – Normally Closed

COM

Common

NO 1

Relay 1 Normally Open

NC 2

Relay 2 Normally Closed

COM

Common

NO 2

Relay 2 Normally Open

Scroll pagebreak

Figure 6: Connector G

...

CONNECTOR

INPUT / OUTPUT / DESTINATION

SPK +

Positive output to speaker

SPK -

Negative output to speaker

AIN 2

Audio input from Processor

GND

Ground input from Processor

MIC

Positive input from microphone

GND

Negative input from microphone

Scroll pagebreak

Figure 7: Connector L – Keypad Connection - 19, iQ only

...