This document is an installation and operational reference guide for Enterphone 19, Enterphone 21, and EnterphoneiQ panels, and Enterphone Kiosks.

...

Enterphone iQ

Enterphone 19

Image RemovedImage Added

Choosing an appropriate install location

...

Note

DO NOT connect the product to power or power up the product yet.

Anchor
figure-1
figure-1

Image RemovedImage Added

Anchor
figure-2
figure-2

Image RemovedImage Added

Mount the product

...

Secure the unit to the wall using the supplied screws. If some screws are using wall anchors, secure the screws to the wall studs first.

Ground Connection

All Enterphone models have an earth-ground connection which must be permanently connected to building earth by a skilled person. Refer to “E. Protective Earth” in Fig 1 and Fig 2 to make the connections.

Section 4: Powering Up Your Panel and Kiosk

All panels are powered by one 5A 12VDC power supply. These power supplies must be connected to standard mains power outlets. Use a minimum 18AWG at a maximum length of 50 feet. Always ensure that power connections and inputs are secure BEFORE activating the panel and that they have been installed by an Identiv approved technician. External power input needs to be connected at the power strip “B. 12VDC” as per the marked polarity in the above Figures 1 and 2.

...

Supplied voltage above or below the above specifications can result in damage to internal components and processes and may void the manufacturer warranty.

The cables used to connect power to Enterphone panels must meet the following requirements:

Length

Minimum Gauge

up to 25 feet / 7.5m

14 AWG

up to 40 feet / 12m

12 AWG

After installing the Enterphone and connecting power, the power cable must be labeled with their max voltage and current. A label is provided with your Enterphone and must be attached near the transformer output.

Section 5: Virtual Access and Programming

  • Tenant and access updating of the panel is accomplished through the Identiv Web Graphical User Interface (GUI) (see figure below). The Web Administration and login Page for this GUI is accessible via any standard Web Browser, provided that the PC is on the same Local Area Network as the panel. The default IP address for each panel is 192.168.123.101

    Image Removed

     

Info

Please refer to the EnterphoneTM Software Administration Guide for additional information concerning the configuration and management of your panel or kiosk.

  • The default login information for the Freedom Web Application is as follows (both are case-sensitive):

...

OUTPUT

VOLTAGE

SWITCH POSITION

TRANSFORMER REQUIREMENTS

SW 1

SW 2

6 VDC

ON

OFF

16VAC / 40VA (TP1640)

12 VDC

OFF

OFF

24VAC or 28VAC / 100VA (T2428100), or 16VAC / 100 VA (T16100) IDENTIV FACTORY DEFALUT SETTING – DO NOT ALTER

24 VDC

OFF

ON

28VAC / 175VA (T2428175)

Figure 4: Connector E

...

 

CONNECTOR

INPUT / OUTPUT / DESTINATION

DT 1

Door Trip 1

DT 2

Door Trip 2

GND

Door Trip 1 Ground

EB 1

Exit Button 1

EB 2

Exit Button 2

GND

Door Trip 2 Ground

GPO 1

General Purpose Output 1 – IDENTIV INTERNAL USE ONLY

GPO 2

General Purpose Output 2 – IDENTIV INTERNAL USE ONLY

LOCK

Postal Lock

GND

Postal Lock Ground

...