This document is an installation and operational reference guide for Enterphone 19, Enterphone 21, and EnterphoneiQ panels, and Enterphone Kiosks.
...
Enterphone iQ |
Enterphone 19 |
Choosing an appropriate install location
...
Note |
---|
DO NOT connect the product to power or power up the product yet. |
| ||||||
|
Mount the product
...
Secure the unit to the wall using the supplied screws. If some screws are using wall anchors, secure the screws to the wall studs first.
Ground Connection
All Enterphone models have an earth-ground connection which must be permanently connected to building earth by a skilled person. Refer to “E. Protective Earth” in Fig 1 and Fig 2 to make the connections.
Section 4: Powering Up Your Panel and Kiosk
All panels are powered by one 5A 12VDC power supply. These power supplies must be connected to standard mains power outlets. Use a minimum 18AWG at a maximum length of 50 feet. Always ensure that power connections and inputs are secure BEFORE activating the panel and that they have been installed by an Identiv approved technician. External power input needs to be connected at the power strip “B. 12VDC” as per the marked polarity in the above Figures 1 and 2.
...
Supplied voltage above or below the above specifications can result in damage to internal components and processes and may void the manufacturer warranty.
The cables used to connect power to Enterphone panels must meet the following requirements:
Length | Minimum Gauge |
---|---|
up to 25 feet / 7.5m | 14 AWG |
up to 40 feet / 12m | 12 AWG |
After installing the Enterphone and connecting power, the power cable must be labeled with their max voltage and current. A label is provided with your Enterphone and must be attached near the transformer output.
Section 5: Virtual Access and Programming
Tenant and access updating of the panel is accomplished through the Identiv Web Graphical User Interface (GUI) (see figure below). The Web Administration and login Page for this GUI is accessible via any standard Web Browser, provided that the PC is on the same Local Area Network as the panel. The default IP address for each panel is 192.168.123.101
Info |
---|
Please refer to the EnterphoneTM Software Administration Guide for additional information concerning the configuration and management of your panel or kiosk. |
The default login information for the Freedom Web Application is as follows (both are case-sensitive):
...
OUTPUT VOLTAGE | SWITCH POSITION | TRANSFORMER REQUIREMENTS | |
SW 1 | SW 2 | ||
6 VDC | ON | OFF | 16VAC / 40VA (TP1640) |
12 VDC | OFF | OFF | 24VAC or 28VAC / 100VA (T2428100), or 16VAC / 100 VA (T16100) IDENTIV FACTORY DEFALUT SETTING – DO NOT ALTER |
24 VDC | OFF | ON | 28VAC / 175VA (T2428175) |
Figure 4: Connector E
...
CONNECTOR | INPUT / OUTPUT / DESTINATION |
---|---|
DT 1 | Door Trip 1 |
DT 2 | Door Trip 2 |
GND | Door Trip 1 Ground |
EB 1 | Exit Button 1 |
EB 2 | Exit Button 2 |
GND | Door Trip 2 Ground |
GPO 1 | General Purpose Output 1 – IDENTIV INTERNAL USE ONLY |
GPO 2 | General Purpose Output 2 – IDENTIV INTERNAL USE ONLY |
LOCK | Postal Lock |
GND | Postal Lock Ground |
...