In System->Devices, check “Device Discovery Tool” checkbox
Click the IDENTIV EG-2 (Model FR-50-40-SB) Devices tab
Click “Scan Devices” button. All IDENTIV EG-2s (Model FR-50-40-SB) in the network will appear in the data table.
To configure IDENTIV EG-2 (Model FR-50-40-SB), click the ID/Mac address of the unit:
IDENTIV EG-2 (Model FR-50-40-SB) Configuration Screen
This Configuration screen will display the software version, OS, Application, and Model number details of the IDENTIV EG-2 (FR-40-50-SB).
By default, IDENTIV EG-2 (Model FR-50-40-SB) uses DHCP addresses. To configure Static IP, use the Type dropdown button Select STATIC type and fill in the corresponding IP addresses:
IDENTIV EG-2 (Model FR-50-40-SB) can connect to a primary and a secondary PRIMIS server. PRIMIS server addresses can either be IP addresses or DNS names. To configure PRIMIS server address(s) fill out the two Server IP fields.
To enable a secured TLS connection to the PRIMIS server, check the TLS enabled checkbox on the configuration page:
Lead Bridge(s)PRIMIS Administrators can designate one or more IDENTIV EG-2 (Model FR-50-40-SB)s in the fleet as “Lead Bridge(s)”. A Lead bridge facilitates global I/O access to the rest of the “Member” bridges.*note: it is highly recommended that Lead Bridge(s) use static IP’s.
Member Bridge(s)“Member” bridges need to know the IP address(s) of “Lead” bridges so as to forward Global I/O requests to the whole IDENTIV EG-2 (Model FR-50-40-SB) network. To configure Lead Bridge Host IP, uncheck Lead Bridge checkbox and enter IP:
IDENTIV EG-2 (Model FR-50-40-SB) is able to use NTP to sync its system clock. To configure NTP, enter the NTP server’s address and check “enabled.” By default, the NTP server address is pool.ntp.org.*note: for NTP to work, please make sure a legitimate Name Server is configured on the IDENTIV EG-2 (Model FR-50-40-SB).
After the TCP connection is established between the PRIMIS server and the IDENTIV EG-2 (Model FR-50-40-SB), we need to install the PRIMIS CA certificate and the client certificate on the IDENTIV EG-2 (Model FR-50-40-SB) by clicking the “Install Certificate” button. The client certificate, together with the PRIMIS CA certificate, is used for the MQTT authentication.
If the server is configured as a multi-principal spoke database server, the following additional steps are required before the IDENTIV EG-2 (Model FR-50-40-SB) can be configured.
Go to System->Utilities->Server Activation.
Enter the configuration for the Enterprise License Server and click “Update” to update the license server information.
Go to System->IDENTIV EG-2 (Model 50-40-SB) Devices.
Click the “Install Server Certificate” button to install the server certificate from the Enterprise License Server.
If the server is configured as a replica database server, the following additional steps are required before the IDENTIV EG-2 (Model FR-50-40-SB)s can be configured.
Go to System->Utilities->Server Activation.
Enter the configuration for the Root CA Server and click “Update” to update the license server information.
Go to System->IDENTIV EG-2 (Model FR-50-40-SB) Devices.
Click the “Install Server Certificate” button to install the server certificate from the Enterprise License Server.
In System->Devices, check “Device Discovery Tool” checkbox
Click IDENTIV EG-2 (Model FR-50-40-SB) Devices tab
To enroll an IDENTIV EG-2 (Model FR-50-40-SB) Device, click the Import button.
On the next page, enter the device’s name and click Save.
The IDENTIV EG-2 (Model FR-50-40-SB) Device is now enrolled into PRIMIS Server. Administrators can now assign the device to Controlled Areas.
Goto System-> IDENTIV EG-2 (Model 50-40-SB) Devices
Under Actions, there are a few control buttons to manage, troubleshoot, and update IDENTIV EG-2 (Model FR-50-40-SB) devices:
Enroll IDENTIV EG-2 (Model FR-50-40-SB) Device
Sync IDENTIV EG-2 (Model FR-50-40-SB) Database
View Device Logs
Ping/Identify IDENTIV EG-2 (Model FR-50-40-SB) Device. Status LED on the device will alternately flash red, green and blue for 30 seconds.
Reboot Device
Download the Application or OS firmware
IDENTIV EG-2 (Model FR-50-40-SB) device is able to synchronize its onboard database with the PRIMIS server as frequently as every hour. This onboard database allows IDENTIV EG-2s (Model FR-50-40-SB) to function independently during PRIMIS server outages or network failures. To assign sync schedules, simply click the corresponding checkbox under Device Sync Schedule.
PRIMIS Server can store IDENTIV EG-2 (Model FR-50-40-SB) Applications and OS images for updates.
To upload the Application Image, Click the “App” tab under TRN. Click “Choose File”, select the image (*.strn) file, and click [ + ] to upload.
To delete the image file, click the [ x ] button for the image.
To upload OS Image, first, click the “OS” tab under TRN. Click “Choose File”, select the image (*.strn) file, and click [ + ] to upload.