AFTER activation, you can reach Identiv Direct Technical Support at +1 (877) 447-7249 or email inquiries to: support@identiv.com
Version | REV A |
---|---|
Date | 06-24-2024 |
Part Number | FR-EM-40-100-K |
Table of Contents | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Section 1: What is in the Box
...
Item | Part # | Quantity | |||
---|---|---|---|---|---|
Enterphone Unit | FR-50-25-13-AD2M | 1 | |||
POTS Surge Protector | 115243R3R | 1 | |||
TransformerTransformer (24VAC/50VA) | 115242R3R | 1 | |||
Keys | FR-368-2336 | 2 | |||
Security Screw Tool | FR-194368-10031500 | 1 | |||
Installation Guide | FR-EM-40-100-K | 1 | |||
Enterphone kiosk Kiosk Configuration Sheet | FR-CS-40-KS | 1 | Keys |
| 2 |
Section 2: Accessories and Modifications
...
Section 3: Physical Access
Physical The physical access to your new kiosk is secured through the keyed lock mechanism located side of the kiosk.
To ensure proper operation of the locking mechanism, ensure that the lock strike remains perpendicular to the leading edge of the kiosk when the unit is open and showing the strike. If the lock strike is not in the correct position the mechanism may not effectively lock the kiosk.
It is strongly recommended that keys be copied after purchase and placed in a documented and secured location to allow access to the kiosk as needed. Loss of keys will require physical removal and replacement of the lock at the expense of the customer. Lock replacement or modification must be completed by a technician approved by Identiv. Any uncertified or third-party modification of the lock mechanism will immediately void the manufacturer's warranty.
...
through the back access panel that is attached via secure screws.
To gain access to the internal connections use the included security screw tool to remove the 10 rear access panel screws.
Note |
---|
Note: The security screws can only be removed using the included tool. |
Section 4: Installing your Enterphone
Before you begin
Check that your Enterphone product includes the following mounting hardware:
...
Item
...
Quantity
...
¼"–20 × 2" stainless steel self-tapping screw, Phillips head
(DIN ISO 7049 type H)
...
4
...
Drywall anchor
...
Identify the appropriate mounting diagram for your Enterphone product below.
...
...
Mounting Plate Dimensions
...
Choosing an appropriate install location
...
Your Enterphone is secured to the wall by four screwson concrete. For maximum strength, choose a location where all four screws can be anchored in wall studs. If this is not possible, at least two screws MUST be anchored in wall studs, with the remaining two screws using the supplied drywall anchors. If your installation site does not permit at least two screws to be anchored in wall studs, please contact your Identiv sales rep to discuss alternative solutionsconcrete or the substrate the panel is being mounted on. There are 4 x 5/8" holes in the base of the Kiosk and all 4 should be used to secure the panel to the ground. Typical installation is in concrete; use a 1/2" x 5" (minimum 4" depending on the thickness of the concrete) concrete anchor.
Use an anchor suitable for the material they are mounting it on, and make sure they use all 4 mounting holes.
Protecting your Enterphone product
...