AFTER activation, you can reach Identiv Direct Technical Support at +1 (877) 447-7249 or email inquiries to: support@identiv.com
Consumer Information
a) This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA. Inside this equipment, there is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
b) An applicable certification jacks Universal Service Order Codes (USOC) for the equipment is provided (i.e., RJ11C) in the packaging with each piece of approved terminal equipment.
c) A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug are provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions for details.
d) The REN is used to determine the number of devices that may be connected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. [For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US:AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label.]
e) If the equipment FR-50-125-13-AD2M causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn't practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
f) The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.
g) Should you experience trouble with this equipment, please contact Identiv,1900-B Carnegie Ave., Santa Ana, CA 92705 USA, +1 888.809.8880 for repair or warranty information. If the equipment is causing harm to the telephone network, the telephone company may request that you disconnect the equipment until the problem is resolved.
h) Connection to party line service is subject to state tariffs. Contact the state public utility commission, public service commission, or corporation commission for information.
If your home has specially wired alarm equipment connected to the telephone line, ensure the installation of this FR-50-125-13-AD2M does not disable your alarm equipment. If you have questions about what will disable alarm equipment, consult your telephone company or a qualified installer.
Note |
---|
According to telephone company reports, AC electrical surges, typically resulting from lightning strikes, are very destructive to telephone equipment connected to AC power sources. To minimize damage from these types of surges, a surge arrestor is recommended. |
Applicable for Coin or Pay Phone Only
...
Version | REV A |
---|---|
Date | 06-24-2024 |
Part Number | FR-EM-40-100-K |
Table of Contents | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Section 1: What is in the Box
...
Item | Part # | Quantity | |||
---|---|---|---|---|---|
Enterphone Unit | FR-50-12525-13-AD2M | 1 | |||
POTS Surge Protector | 115243R3RTransformer (24VAC/50VA) | 115242R3R | 1 | ||
Power Supply | 115242R3R | 1 | |||
Power Supply Barrel ConnectorKeys | FR-368-2336 | 2 | |||
Security Screw Tool | FR-221368-20121500 | 1 | |||
Installation Guide | FR-EM-40-100-K | 1 | |||
Enterphone kiosk Kiosk Configuration Sheet | FR-CS-40-KS | 1 | Keys |
| 2 |
Section 2: Accessories and Modifications
...
Section 3: Physical Access
Physical The physical access to your new kiosk is secured through the keyed lock mechanism located back of the kiosk.
To ensure proper operation of the locking mechanism, ensure that the lock strike remains perpendicular to the leading edge of the kiosk when the unit is open and showing the strike. If the lock strike is not in the correct position the mechanism may not effectively lock the kiosk.
It is strongly recommended that keys be copied after purchase and placed in a documented and secured location to allow access to the kiosk as needed. Loss of keys will require physical removal and replacement of the lock at the expense of the customer. Lock replacement or modification must be completed by a technician approved by Identiv. Any uncertified or third-party modification of the lock mechanism will immediately void the manufacturer's warranty.
...
back access panel that is attached via secure screws.
To gain access to the internal connections use the included security screw tool to remove the 10 rear access panel screws.
Note |
---|
Note: The security screws can only be removed using the included tool. |
Section 4: Installing your Enterphone
Before you begin
Check that your Enterphone product includes the following mounting hardware:
...
Item
...
Quantity
...
¼"–20 × 2" stainless steel self-tapping screw, Phillips head
(DIN ISO 7049 type H)
...
4
...
...
2
Identify the appropriate mounting diagram for your Enterphone product below.
...
...
Mounting Plate Dimensions
...
Choosing an appropriate install location
...
Your Enterphone is secured to the wall by four screwson concrete. For maximum strength, choose a location where all four screws can be anchored in wall studs. If this is not possible, at least two screws MUST be anchored in wall studs, with the remaining two screws using the supplied drywall anchors. If your installation site does not permit at least two screws to be anchored in wall studs, please contact your Identiv sales rep to discuss alternative solutionsconcrete or the substrate the panel is being mounted on. There are 4 x 5/8" holes in the base of the Kiosk and all 4 should be used to secure the panel to the ground. Typical installation is in concrete; use a 1/2" x 5" (minimum 4" depending on the thickness of the concrete) concrete anchor.
Use an anchor suitable for the material they are mounting it on, and make sure they use all 4 mounting holes.
Protecting your Enterphone product
...
Supplied voltage above or below the above specifications can result in damage to internal components and processes and may void the manufacturer manufacturer’s warranty.
The cables used to connect power to the Enterphone kiosk must meet the following requirements:
...
Tenant and access updating of the kiosk is accomplished through the Identiv Web Graphical User Interface (GUI). The Web Administration and login page for this GUI are accessible via any standard web browser, provided that the PC is on the same Local Area Network as the kiosk. The default IP address for each kiosk is 192.168.123.101.
Info |
---|
Please refer to the Primis Enterphone Solution Guide for additional information concerning the configuration and management of your kiosk. |
...
| Screen Size (inches) | Overall Dimensions (inches) | Weight | Operating Temperature | Power Requirements | Touch Function Capabilities | ||
EnterphoneTM Kiosk | 19 in | 50.0 x 18.0 x 12.0 | 96 | 55" 3/4" X 23" X 14" 7/8" (Top) | 101 lbs | 0o – 49o C | 12v DC, 60 VA min24AC 50VA | YES |
Terminal Block 1
Connections for Terminal Block 1 (TB1)
...