By default, IDENTIV EG-2 (Model FR-50-40-SB) uses DHCP addressesa static IP address of 192.168.123.103. To configure Static IP or DHCP, use the Type dropdown button Select STATIC or DHCP type and fill in the corresponding IP addresses:required information.
Assigning PRIMIS Server Address
...
Lead Bridge(s)PRIMIS Administrators can designate one or more IDENTIV EG-2 (Model FR-50-40-SB)s in the fleet as “Lead Bridge(s)”. A Lead bridge facilitates global I/O access to the rest of the “Member” bridges.*note: it is highly recommended that Lead Bridge(s) use static IP’s.
Member Bridge(s)“Member” bridges need to know the IP address(s) of “Lead” bridges so as to forward Global I/O requests to the whole IDENTIV EG-2 (Model FR-50-40-SB) network. To configure Lead Bridge Host IP, uncheck Lead Bridge checkbox and enter IP:
NTP Configuration
IDENTIV EG-2 (Model FR-50-40-SB) is able to use NTP to sync its system clock. To configure NTP, enter the NTP server’s address and check “enabled.” By default, the NTP server address is pool.ntp.org.*note: for NTP to work, please make sure a legitimate Name Server is configured on the IDENTIV EG-2 (Model FR-50-40-SB).
...
After the TCP connection is established between the PRIMIS server and the IDENTIV EG-2 (Model FR-50-40-SB), we need to install the PRIMIS CA certificate and the client certificate on the IDENTIV EG-2 (Model FR-50-40-SB) by clicking the “Install Certificate” button. The client certificate, together with the PRIMIS CA certificate, is used for the MQTT authentication.
Please make sure the EG-2 is enrolled prior to installing the TLS certificate; otherwise, the certificate installation will fail.
IDENTIV EG-2 (Model FR-50-40-SB) Configuration on Multi-Principal Spoke Database Server
...