Scan and Detect

...

IDENTIV EG-2s (Model FR-50-40-SB) in the Network

  1. In System->Devices, check “Device Discovery Tool” checkbox

  2. Click the

...

  1. IDENTIV EG-2 (Model FR-50-40-SB) Devices tab

...

  1. Image Added

  2. Click “Scan Devices” button. All

...

  1. IDENTIV EG-2s (Model FR-50-40-SB) in the network will appear in the data table.

...

  1. Image Added

  2. To configure

...

Smart Bridge Configuration Screen

...

  1. IDENTIV EG-2 (Model FR-50-40-SB), click the ID/Mac address of the unit:

...

  1. Image Added

  2. IDENTIV EG-2 (Model FR-50-40-SB) Configuration Screen

    Image Added

This Configuration screen will display the software version, OS, Application, and Model number details of the IDENTIV EG-2 (FR-40-50-SB).

...

Assigning IP Address

  1. By default,

...

  1. IDENTIV EG-2 (Model FR-50-40-SB) uses a static IP address of 192.168.123.103. To configure Static IP or DHCP, use the Type dropdown button

...

  1. Select STATIC or DHCP type and fill in the

...

  1. required information.

    Image Modified

Assigning

...

PRIMIS Server Address

...

  1. IDENTIV EG-2 (Model FR-50-40-SB) can connect to a primary and a secondary

...

  1. PRIMIS server.

...

  1. PRIMIS server addresses can either be IP addresses or DNS names. To configure

...

  1. PRIMIS server address(s) fill out the two Server IP fields.

    Image Modified

Enabling TLS connection to

...

PRIMIS Server

  1. To enable a secured TLS connection to the

...

  1. PRIMIS server, check the TLS enabled checkbox on the configuration page:

    Image Modified

Setting Up

...

Lead EG-2 (release 1.1 and above)

...

  1. Lead Bridge(s)

...

  1. PRIMIS Administrators can designate one or more

...

  1. IDENTIV EG-2 (Model FR-50-40-SB)s in the fleet as

...

  1. “Lead Bridge(s)”. A

...

  1. Lead bridge facilitates global I/O access to the rest of the “Member” bridges.*note: it is highly recommended that

...

  1. Lead Bridge(s) use static IP’s.

...

  1. Image Added

  2. Member Bridge(s)“Member” bridges need to know the IP address(s) of

...

  1. “Lead” bridges so as to forward Global I/O requests to the whole

...

  1. IDENTIV EG-2 (Model FR-50-40-SB) network. To configure

...

  1. Lead Bridge Host IP, uncheck

...

  1. Lead Bridge checkbox and enter IP:

...

  1. Image Added

NTP Configuration

...

  1. IDENTIV EG-2 (Model FR-50-40-SB) is able to use NTP to sync its system clock. To configure NTP, enter the NTP server’s address and check

...

  1. “enabled.By default, the NTP server address is pool.ntp.org.*note: for NTP to work, please make sure a legitimate Name Server is configured on the

...

  1. IDENTIV EG-2 (Model FR-50-40-SB).

    Image Modified

Installing TLS Certificate

  1. After the TCP connection is established between the

...

  1. PRIMIS server and the

...

  1. IDENTIV EG-2 (Model FR-50-40-SB), we need to install the

...

  1. PRIMIS CA certificate and the client certificate on the

...

  1. IDENTIV EG-2 (Model FR-50-40-SB) by clicking the “Install Certificate” button. The client certificate, together with the

...

  1. PRIMIS CA certificate

...

  1. , is used for the MQTT authentication.

...

  1. Image Added

Please make sure the EG-2 is enrolled prior to installing the TLS certificate; otherwise,  the certificate installation will fail.

IDENTIV EG-2 (Model FR-50-40-SB) Configuration on Multi-Principal Spoke Database Server

If the server is configured as a multimaster multi-principal spoke database server, the following additional steps are required before the Smart Bridges IDENTIV EG-2 (Model FR-50-40-SB) can be configured.

  1. Go to System->Utilities->Server Activation.

  2. Enter the configuration for the Enterprise License Server and click “Update” to update the license server information.

...

  1. Image Added

  2. Go to System

...

  1. ->IDENTIV EG-2 (Model 50-40-SB) Devices.

  2. Click the “Install Server Certificate” button to install the server certificate from the Enterprise License Server.

...

  1. Image Added

IDENTIV EG-2 (Model FR-50-40-SB) Configuration on the

...

Replica Database Server

If the server is configured as a slave replica database server, the following additional steps are required before the Smart Bridges IDENTIV EG-2 (Model FR-50-40-SB)s can be configured.

  1. Go to System->Utilities->Server Activation.

  2. Enter the configuration for the Root CA Server and click “Update” to update the license server information.

...

  1. Image Added

  2. Go to System-

...

  1. >IDENTIV EG-2 (Model FR-50-40-SB) Devices.

  2. Click the “Install Server Certificate” button to install the server certificate from the Enterprise License Server.

...

  1. Image Added

Enrolling

...

IDENTIV EG-2 (Model FR-50-40-SB) Device in PRIMIS Server

  1. In System->Devices, check “Device Discovery Tool” checkbox

  2. Click

...

  1. IDENTIV EG-2 (Model FR-50-40-SB) Devices tab

...

  1. Image Added

  2. To enroll

...

  1. an IDENTIV EG-2 (Model FR-50-40-SB) Device, click the Import button.

    Image Modified

  2. On the next page, enter the device’s name and click Save.

...

  1. Image Added

  2. The

...

  1. IDENTIV EG-2 (Model FR-50-40-SB) Device is now enrolled into

...

  1. PRIMIS Server. Administrators can now assign the device to Controlled Areas.

...

  1. Image Added

Managing

...

IDENTIV EG-2 (Model FR-50-40-SB) Devices

  1. Goto System->

...

  1. IDENTIV EG-2 (Model 50-40-SB) Devices

  2. Under Actions, there are a few control buttons to manage, troubleshoot, and update

...

  1. IDENTIV EG-2 (Model FR-50-40-SB) devices:

    Image Modified

...

Enroll Smart Bridge IDENTIV EG-2 (Model FR-50-40-SB) Device

...

Sync Smart Bridge IDENTIV EG-2 (Model FR-50-40-SB) Database

...

View Device Logs

Ping/Identify Smart Bridge IDENTIV EG-2 (Model FR-50-40-SB) Device. Status LED on the device will alternately flash red, green and blue for 30 seconds.

...

Reboot Device

Download the Application or OS firmware

Managing Sync schedules

Smart Bridge IDENTIV EG-2 (Model FR-50-40-SB) device is able to synchronize its onboard database with Freedom the PRIMIS server as frequently as every hour. This onboard database allows Smart Bridges IDENTIV EG-2s (Model FR-50-40-SB) to function independently during Freedom PRIMIS server outage outages or network failurefailures. To assign sync schedules, simply click the corresponding checkbox under Device Sync Schedule.

...

Managing Application and OS Images

Freedom PRIMIS Server can store Smart Bridge Application IDENTIV EG-2 (Model FR-50-40-SB) Applications and OS images for updates.

...

  1. To upload the Application Image, Click the “App” tab under TRN. Click “Choose File”, select the image (*.strn) file, and click [ + ] to upload.

  2. To delete the image file, click the [ x ] button for the image.

  3. To upload OS Image, first, click the “OS” tab under TRN. Click “Choose File”, select the image (*.strn) file, and click [ + ] to upload.