Live Search |
---|
Table of Contents |
---|
Introduction
This document details the Physical Access Control Reader uTrust Scramblepad TS and its basic Operational and installation procedures.
Reader
Functionality
uTrust Scramblepad TS is a physical access control smart card reader that can read HF and LF contactless credentials, conforming to the following standards: ISO 14443 A & B, ISO15693 with a Randomly displayed keypad pin entry for additional security. The reader can interface with an access control system equipped with a RS-Hirsch serial interface. Only Listed Identiv control units are compatible for use with the DS47L-SSP-TS.
Reader Parts
a. Front/Top Casing
b. Rear view with back plate
Product details
Product Name | uTrust Scramblepad TS |
Model Name | DS47L-SSP-TS |
Device Type | RFID reader, 13.56MHz (HF) / 125 KHz (LF), keypad |
Type of equipment | Suitable for Indoor use |
Interface Type | Phoenix connectors |
Voltage Rating | 28V DC |
Current Rating @28 V | 240 mA |
Communication protocol | RS-HIRSCH protocol |
Specifications
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.
Model | Operating Voltage | Current @ 12V | Operating temp | Operating Humidity |
---|---|---|---|---|
DS47L-SSP-TS | 28 VDC | 240 mA | 0 to +49C | 85 +/-5 % RH |
Class 2 power source with 28VDC to be used to power the reader.
Only listed Identiv control units are compatible for use with the DS47L-SSP-TS.
Power up and Testing
1 Turn power on
Beep sound comes.
2 Present a card
HF card, LF card
The green LED glows when passed, RED LED when failed with a short Beep.
3 Press Start Key
Scrambling display with buzzer tone & displays scrambled key.
This is the default reader behavior.
Label
Installation
Install the respective mounting box in to the wall.
Take the cable from the backside of the reader as per the pin outs in the label drawing.
Fix the four screws at the corner into the mounting box.
Fix the bezel on the top of the installed reader.
Certifications
FCC
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Information to user
Changes or modifications not expressly approved by Identiv could void the user's authority to operate the equipment.
IC
This device complies with Industry Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
UL 294
Access Control Performance Levels
Destructive attack | Level IV |
Line Security | Level I |
Endurance | Level I |
Standby Power | Level I |