Live Search |
---|
Introduction
This document details the Physical Access Control Reader TouchSecure® and its basic operational and installation procedures. It covers the details of the Wall mount form-factor reader.
Model: Connectivity/Standard WM.
The reader comes in two variants for interfacing with the control panel:
Pigtail – 8100ABP, 8110ABP.
Phoenix connectors – 8100ABT, 8110ABT, 8130ABC.
P-refers to Pigtail, T- refers to Terminal (Phoenix header).
The reader comes in three variants in functionality
Standard HF Only - 8100ABP, 8100ABT.
Standard HF LF - 8110ABP, 8110ABT.
Connectivity HF LF - 8130ABC.
P-refers to Pigtail, T- refers to Terminal (Phoenix header), C- refers to connectivity.
In connectivity, only Terminal version is available.
Reader
Functionality
TouchSecure® is a physical access reader that can read HF and LF contactless credentials .The reader can interface with an access control system equipped with a Wiegand or RS485 serial interface Control Panel. It can also be interfaced with a Host Sever / Control Panel that supports Ethernet interface. User interfaces include RGB LED’s and Buzzer.
Reader Parts
The reader consists of the following main parts.
a.Touch Secure® reader with Casing
b.Back Plate
Reader Variants
Product details
Model Name | Connectivity/Standard Wall Mount |
Device Type | RFID reader, 13.56MHz (HF) / 125 KHz (LF) |
Type of equipment | Potted reader. |
Interface Typ | Pigtail Cable (11 Core + Drain) or Phoenix connectors and RJ45 |
Voltage Rating (8130ABC) | 6-16V DC or 48VDC on RJ45 Connector |
Voltage Rating (All other models): | 5-16V DC |
Communication protocol | Wiegand, RS485 (2wire - Half Duplex), 10BaseT ETH |
* Communication via Wiegand and OSDP was evaluated by UL and serves as the interface between the reader and panel. , Communication via RS485, OSDP or Ethernet was not evaluated by UL. |
Specifications
Model | Operating Voltage | Current @ 12V | Operating temp |
---|---|---|---|
8100ABP | 5-16 VDC | Refer graph in section “Rated current at different operating voltages” | -35 to +65 Deg C |
8110ABP | 5-16 VDC | Refer graph in section “Rated current at different operating voltages” | |
8130ABC | 6-16 VDC | Refer graph in section “Rated current at different operating voltages” | 0 to +49 Deg C |
POE@ 48VDC |
*POE sourcing equipment shall be UL 294 or UL 294B Listed with Class 2 output
When the readers use POE as a power source, the power input wiring from the control unit (i.e. Red and Black for 8130) shall be disconnected.
The maximum length of the Ethernet cable when using POE as the power source in UL installations is limited to 30 meters (98.5 feet).
Standby Power is not provided by the Card Readers. The Standby Power Level is dependent on the external power source connected to the Card Reader.
All wiring or cables to the Card Readers shall be the shielded type
Only UL Listed POE sourcing equipment, or UL Listed power-limited power supply, or power-limited output from UL Listed control panel shall be used for the Power-Over- Ethernet feature. Cat 5e cabling is the minimum performance category recommended. These Card Readers when using POE feature are not intended for outside wiring as covered by Article 800 of the US National Electrical Code, NFPA 70.
Rated current at different operating voltages
Rated current for Model 8100
Voltage (V) | Average Current (mA) | Peak Current (mA) |
---|---|---|
5 | 147 | 166 |
8 | 150 | 178 |
10 | 116 | 138 |
12 | 97 | 114 |
14 | 83 | 100 |
16 | 73 | 86 |
Rated current for Model 8110
Voltage (V) | Average Current (mA) | Peak Current (mA) |
---|---|---|
5 | 147 | 166 |
8 | 150 | 178 |
10 | 116 | 138 |
12 | 97 | 114 |
14 | 83 | 100 |
16 | 73 | 86 |
Rated current for Model 8130
Rated current for 6-16V input
Voltage (V) | Average Current (mA) | Peak Current (mA) |
---|---|---|
6 | 280 | 308 |
8 | 261 | 292 |
10 | 217 | 257 |
12 | 172 | 202 |
14 | 148 | 173 |
16 | 131 | 156 |
Rated current for POE
Voltage (V) | Average Current (mA) | Peak Current (mA) |
---|---|---|
37 | 65 | 70 |
48 | 50 | 55 |
57 | 45 | 50 |
Installation details
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.
Parts List
TouchSecure® reader -1
Screws (A #6-18X1.5" SS ) - 4Nos – Back Plate mounting screws for Wall
Snake Eye Screw (SMF #6-32X5/16" SS) – 1 No- Top casing mounting security screw
Screws (SMF #6-32x3/8" SS) - 3 No’s - 1 casing to back plate mounting screw and 2 Junction Box mounting screws
Nylon anchor plug -4 Nos
6 pin phoenix plug (Phoenix connector version only) – 2 Nos
Back Plate
Recommended Infrastructure
All cabling and wiring shall be UL Listed and/or UL Recognized
All readers shall be powered by UL listed POE sourcing equipment, UL listed power-limited power supply, or power-limited output from UL listed control panel
Cable Wiegand | 22AWG Shielded cable. ( Cable P No : ALPHA WIRE, P/N 1299/10C) |
Cable RS485 | RS485 for 1000m** (4000ft) 24AWG STP |
Cable RJ45 | Cat5e / Cat6 |
Linear DC PS | 5-16 V, 1A min. |
** Tested in lab conditions up to 115Kbaud
Wiring Information
Cable Color codes for Pig Tail Reader
Table 1
& Do not connect when reader is powered by Power over Ethernet
Pin out for Phoenix Connector Reader
Table 2
Pin | Cable color | Description | Comment |
---|---|---|---|
P1.1 | Orange | LED Green | |
P1.2 | White | Data 1 | |
P1.3 | Green | Data 0 | |
P1.4 | Black | Drain | Connect drain to Cable shield |
P1.5 | Black + White | Gnd | |
P1.6 | Red | Power | Do not connect when reader is powered by PoE |
P2.1 | Blue | Hold | |
P2.2 | Violet | Tamper | |
P2.3 | Gray | RS485- | |
P2.4 | Pink | RS485+ | |
P2.5 | Yellow | Buzzer | |
P2.6 | Brown | LED Red |
Note |
---|
During Wiring make sure that the +VDC lines does not make contact with any other cables, as it might affect reader functionality/ cause damage to the reader. |
Mounting the Reader
Location of mounting holes on wall
Reader Installation Steps
a. Make holes on the wall as per the image above.
b. Insert the nylon screw plugs into the wall.
c. Connect the wires as per the Table 1 or Table 2.
d. TouchSecure® reader with Bottom Casing is to be now secured onto the wall using the Screws (A #6-18X1.5" SS ).
e. The top casing can be inserted onto the bottom casing.
f. Secure the Top and bottom casing by the Snake Eye Screw (SMF #6-32X5/16" SS).
Power up and Testing
Turn power on
The LED blinks 3 times green with a long beep, then turns red.Present a card
The LED blinks green, and a short Beep is emitted .
This is the default reader behavior.
Certifications
FCC
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Information to user
Changes or modifications not expressly approved by Identiv could void the user's authority to operate the equipment.
IC
This Class B digital apparatus complies with Canadian ICES-003.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may cause undesired operation of the device.
CE
Identiv hereby declares that the TouchSecure® Model: Connectivity WM device mentioned herein is in compliance with the essential requirements and other relevant portions of the Directive R&TTE 1999/5/EC.
UL 294
Communication via Wiegand and OSDP was evaluated by UL and serves as the interface between the reader and panel
Communication via Ethernet was not evaluated by UL.
The maximum length of the Ethernet cable when using POE as the power source in UL installations is limited to 30 meters (98.5 feet).
UL 294 Access Control Performance Levels
Destructive attack | Level IV |
Line Security | Level I |
Endurance | Level I |
Standby Power | Level I |