  1. In System->Devices, check “Device Discovery Tool” checkbox

  2. Click the IDENTIV EG-2 (Model FR-50-40-SB) Devices tab

  3. Click “Scan Devices” button. All IDENTIV EG-2s (Model FR-50-40-SB) in the network will appear in the data table.

  4. To configure IDENTIV EG-2 (Model FR-50-40-SB), click the ID/Mac address of the unit:

  5. IDENTIV EG-2 (Model FR-50-40-SB) Configuration Screen

    Image RemovedImage Added

This Configuration screen will display the software version, OS, Application, and Model number details of the IDENTIV EG-2 (FR-40-50-SB).

...

  1. To enable a secured TLS connection to the PRIMIS server, check the TLS enabled checkbox on the configuration page:

Setting Up

...

Lead EG-2 (release 1.1 and above)

  1. Master Lead Bridge(s)PRIMIS Administrators can designate one or more IDENTIV EG-2 (Model FR-50-40-SB)s in the fleet as “Master “Lead Bridge(s)”. A Master Lead bridge facilitates global I/O access to the rest of the “Member” bridges.*note: it is highly recommended that Master Lead Bridge(s) use static IP’s.

    Image RemovedImage Added

  2. Member Bridge(s)“Member” bridges need to know the IP address(s) of “Master” “Lead” bridges so as to forward Global I/O requests to the whole IDENTIV EG-2 (Model FR-50-40-SB) network. To configure Master Lead Bridge Host IP, uncheck Master Lead Bridge checkbox and enter IP:

    Image RemovedImage Added

NTP Configuration

  1. IDENTIV EG-2 (Model FR-50-40-SB) is able to use NTP to sync its system clock. To configure NTP, enter the NTP server’s address and check “enabled.” By default, the NTP server address is pool.ntp.org.*note: for NTP to work, please make sure a legitimate Name Server is configured on the IDENTIV EG-2 (Model FR-50-40-SB).

...